Adaptronic e420d Basic Select ECU
Product Code: e420
AUD 990.00 Add to cart
Technical Specifications
Attribute |
e420d |
Physical |
|
|
Connectors |
2-plug connector (same as Mazda NA6 and NA8 MX5/Miata) |
|
Physical Dimensions (mm) |
142 x 142 x 33 mm (including mounting tabs) |
|
Mass |
0.4 kg |
|
Looms available |
0.5m long (for connection to existing loom) |
Sensor Interfaces |
|
|
Crank angle sensor type |
3 programmable inputs, reluctor or hall-effect/optical, configurable as triggering ignition timing, injector drive, ignition timing during cranking, or cylinder 1 marker. |
|
Crank angle trigger waveforms |
Sync / trigger / multitooth / missing tooth (versatile programmability) |
|
External Manifold Absolute Pressure (MAP) input |
0 – 5V, 2-point linear calibration, range 0 to 400 kPa (5V supplied by ECU) |
|
Air, water and aux temp inputs |
4k7 pull-up (requires separate thermistor connected to ground), 32-point linearly interpolated calibration, range -30 to 125°C |
|
EGO input |
0 – 1V factory narrowband, or Bosch “wideband” – input impedance 10 MOhm. |
|
Knock input |
High impedance input, filtered |
|
Throttle position (TPS) input |
0-5V (5V supplied by ECU), 2-point calibration |
|
Auxiliary digital inputs |
4 inputs, each configurable as active-high or active-low, 12V tolerant inputs |
Actuator Interfaces |
|
|
Number of injector drivers |
4 |
|
Injector driver waveforms |
Full sequential |
|
Injector driver current |
Optional constant current or peak-hold drive, selectable steady-state current of 0.5A, 0.9A, 1.5A or 1.9A |
|
Number ignition outputs |
4 (using 4th channel disables aux output 1) |
|
Ignition output waveforms |
Selectable as firing on rising edge or falling edge |
|
Ignition output type |
Open-collector with 560Ohm pull-up (allows direct connection to OEM transistor or separate igniter box) |
|
Number of auxiliary outputs |
8 (or 7 if using 4 ignition channels) |
|
High current outputs |
Max current 7A (or 3A inductive), 3 of these PWM capable, PWM frequency selectable (23Hz – 2kHz) |
|
Low current outputs |
Max current 200mA – suitable to drive relay coils |
Control Characteristics |
|
|
Map points |
512 cells per fuel/ignition map, dual maps which can be toggled with digital input. |
|
Load determination and Tuning Modes |
Optional Volumetric Efficiency Tuning TPS or MAP based |
|
Injector pulse width resolution |
0.7µs (0 – 44ms) |
|
Ignition resolution |
0.2° (0 – 51°) |
|
Dwell time resolution |
0.1ms (0.1ms – 5ms) |
|
Accelerator pump |
TPS and/or MAP based (configurable proportionality) as well as asynchronous accelerator pump. |
|
Fuel control strategies |
Open loop, closed loop (requires EGO sensor) – can run open loop above a specific MAP if required, target AFR can be set across rev and load ranges. |
|
Fuel correction |
Trim tables based on Coolant Temperature and Air Temperature, Dead-Time correction |
|
Ignition control strategies |
Trim tables based on Coolant Temperature and Air Temperature |
|
Idle control strategies |
Open loop values with a 32-entry temperature table |
|
Main loop speed |
400Hz approx |
AUD 990.00 Add to cart